Table 4 Comparison of the sensitivities of Vitek 2 and MALDI-TOF MS in the identification of selected yeast to the species and genus levels

From: Comparison of biomarker based Matrix Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry (MALDI-TOF MS) and conventional methods in the identification of clinically relevant bacteria and yeast

Organism (n)

Number (%) of isolates with Correct identification to the species level:

Number (%) of isolates with Correct identification to the genus level:

Vitek

MALDI-TOF MS

P value

Vitek

MALDI-TOF MS

P value

Candida albicans (5)

5

5

 

5

5

 

Candida dubliniensis (2)

2

2

 

2

2

 

Candida glabrata (4)

4

4

 

4

4

 

Candida guillermondii (1)a

-

-

 

-

-

 

Candida haemulonii (6)a

-

-

 

-

-

 

Candida kefyr (1)

1

1

 

1

1

 

Candida krusei (4)

4

4

 

4

4

 

Candida parapsilosis (2)

2

2

 

2

2

 

Candida tropicalis (4)

3

4

0.285

4

4

 

Cryptococcus neoformans (1)

1

1

 

1

1

 

Total (23)

22 (95.7)

23 (100.0)

0.312

23 (100.0)

23 (100.0)

 